The
File/Write/Autosave... menu item opens the
Autosave Case/Data panel.
Autosave Case/Data Panel
The
Autosave Case/Data panel is used to specify automatic saving of case and data files at specified intervals during a calculation. See Section
4.3.4 for details.
Controls
Autosave Case File Frequency
specifies the frequency with which case files are saved. For steady flows you will specify the frequency in iterations, and for unsteady flows you will specify it in time steps (unless you are using the explicit time stepping formulation, in which case you will specify the frequency in iterations).
Autosave Data File Frequency
specifies the frequency with which data files are saved. For steady flows you will specify the frequency in iterations, and for unsteady flows you will specify it in time steps (unless you are using the explicit time stepping formulation, in which case you will specify the frequency in iterations).
Overwrite Existing Files
allows you to restrict the number of files saved by
FLUENT if you have limited disc space. Enable the
Overwrite Existing Files option and set the value of the
Maximum Number of Each File Type field.
Maximum Number of Each File Type
specifies the maximum number of files that can be saved at any instance. If you have constraints on the disc space, you can restrict the number of files to be saved using this field. After saving the specified number of files,
FLUENT will overwrite the earliest existing file. The default value for this field is zero which saves all the files.
Filename
specifies the root name for the files that are saved. The iteration or time-step number and an appropriate suffix (
.cas or
.dat) will be added to the specified root name. If the specified
Filename ends in
.gz or
.Z, appropriate file compression will be performed. (See Section
4.1.5 for details about file compression.)